NEW UC INSTRUMENTS GM81022C SALES and UC INSTRUMENTS GM81022C CALIBRATION

 
Custom-Cal has for sale a new UC INSTRUMENTS GM81022C. Also, short calibration turn times minimize downtime and reasonable rates decrease your long-term cost of ownership and minimizes downtime of the UC INSTRUMENTS GM81022C. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
List Price for a new UC INSTRUMENTS GM81022C, $6,980.00   UC INSTRUMENTS GM81022C   Description / Specification:   Spec Sheet 
UC INSTRUMENTS GM81022C C-Band Tunable Laser Module

The UC INSTRUMENTS GM81022C Tunable Laser Module offers superior performance for the test of DWDM components, AWG & PLC components, optical amplifiers, and other general purpose of fiber optical test and measurement applications. A GM8001B mainframe can host 2 Tunable Laser modules. Specifications. Wavelength range: 1525.00 to 1566.00 nm. Output Power: >= 13 dBm. Wavelength resolution: 1.0 pm. Absolute wavelength accuracy: +/- 10 pm, tpy. < 5 pm. Relative wavelength accuracy: +/- 5 pm, Typ. +/- 2 pm. Wavelength repeatability: +/- 2 pm, typ. +/- 1 pm. Wavelength stability (typ., 24 hrs at constant temperature: <= +/- 2 pm. Tuning speed: <= 2 ms per step. Power stability: +/- 0.05 dB, 1 hour. Typ., +/- 0.1 dB, 24 hours. Power repeatability: +/- 0.05 dB. Power linearity: +/- 0.3 dB. Power flatness versus wavelength: 0.3 dB typ., 0.5 dB max.. Side-mode Suppression ratio: >= 50 dBc. Relative intensity noise (RIN. Typ.): < -135 dB. Output optical interface: PM, FC/PC connector. Dimensions: 75 mm H, 32 mm W, 310 mm D [3.5" (L) x 8.5" (W) x 12.5" (H)].



 

Standard Calibration $475.00 *
*This is a Web introductory price for one calibration of the UC INSTRUMENTS GM81022C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your new UC INSTRUMENTS GM81022C sale price and/or UC INSTRUMENTS GM81022C CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: